Продажа и поддержка : Request A Quote
Главная страница Продукцияоборудование для испытаний кабеля

Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666

Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666

    • Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666
    • Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666
    • Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666
    • Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666
  • Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666

    Подробная информация о продукте:

    Место происхождения: КИТАЙ
    Фирменное наименование: AI
    Сертификация: ISO
    Model Number: TUL1666

    Оплата и доставка Условия:

    Количество мин заказа: 1 набор
    Цена: Договоренно
    Упаковывая детали: Фанерный чехол
    Время доставки: 90 дней
    Условия оплаты: Western Union, T/T, L/C
    Поставка способности: 10 комплектов/месяц
    Контакт
    Подробное описание продукта
    Test standard: UL 1666 Function: determining values of flame propagation height
    Тестовый объект: Кабель подъемника Pressure of test chamber: 0-12pa
    Первый этаж: 1,22 м Второй этаж: 3.66m
    Верхний этаж: 2.24m External dimmension: 7.12mx1.3m wide x2.5m long
    Цвет: Серый Measure hole: 305mm by 610mm

    Introduction

    This is a fire test for determining values of flame propagation height for electrical and optical-fiber cables that are for installation vertically in shafts or in vertical runs that penetrate one or more floors.
    The purpose of this test is to determine whether the flame propagation characteristics of these "riser" cables are in accordance with the National Electrical Code.

    Feature

    1. U-shaped pressure gauge: the pressure of the test chamber are maintained at 0-12pa.
    2. Hygrometer: measure the temperature and humidity of the test chamber.
    3. Structure of the test box: the overall structure is made of concrete wall, the first floor is 1.22m, and the second floor is 3.66M. The top floor is 2.24m, and the external dimension is 7.12mx1.3m wide x2.5m long.
    4. The wall structure is a concrete with a density of 1061b/ft3 (1698kd/m), and its thermal conductivity (k) is 0.38btu (0.055w/mk) at 21.1c. The first and second layers are composed of 203mm thick reinforced ordinary weight cement, and the top is composed of a wall structure that can ensure tightness. The measuring holes on the second layer must be vertically above the measuring holes (305mm by 610mm) on the first layer. Each hole is 203mm from the back of the box and 102m from the side of the box
    5. The ignition device is composed of a 1/2 inch steel pipe, a 1/2 inch elbow and a steel ignition dispersion plate.
    6. Install a propane flowmeter at the place of gas injection.
    7. Install exhaust fan and anemometer at the outlet of fan test box.

     

    Flame Propagation Height for Electrical and Optical-fiber Cables Riser Flame Test by UL 1666

    Контактная информация
    Advanced Instruments Co.,Ltd

    Контактное лицо: Mrs. Sandy

    Оставьте вашу заявку (0 / 3000)